Three Core URD 6.35/11KV SWA Armoured Electrical Cable XLPE 3x95SQMM By AS Standard
Construction
Conductor | Compact Stranded Copper Conductor, Class 2 as per IEC 60228 |
Circular solid Copper Conductor, Class 1 as per IEC 60228 | |
Flexible Stranded Copper Conductor, Class 5 as per IEC 60228 | |
Conductor Screen | Semi-conductor |
Insulation | XLPE(Cross-linked polyethylene) |
Insulation Screen | Semi-conductor |
Metalic Shield | Copper Tape Screen or Copper wire & copper tape Shield |
Filler | Fillers strip |
Wrapping Tape | Non woven wrapping tape or lsoh wrapping tape |
Inner Covering | Extruded PVC, or LSOH |
Armour | Steel Tape Armour |
Overall Sheath | PVC, FR-PVC, PE or LSOH |
Standards
International: IEC 60502-2, IEC 60228
China: GB/T 12706.2-2008
Other standards such as BS,DIN and ICEA upon request
Applications
Used for power transmission and distribution line with voltage rated at 35kV and below.
Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.
Specifications
MV(6 to 35kv) Power Cable | |||
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV | No.of Core | Conductor cross-section area(mm2) | |
xlpe insulation | 1 core 3 core | 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm | |
Cu core | Al Core | ||
YJV, N2XSY;PVC sheathed power cable | YJLV, NA2XSY; PVC sheathed power cable | ||
YJV22;steel tape armoured,PVC sheathed power cable | YJLV22;steel tape armoured,PVC sheathed power cable | ||
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable | YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable | ||
pvc insulation | |||
Cu Core | Al Core | ||
VV(VY);PVC(PE)sheathed power cable | VLV(VLY);PVC(PE)sheathed power cable | ||
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable | VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable | ||
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable | VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable |
Technical data
Test voltage | 6 / 10 kV | [kV] | 21 / 5 min. |
12 / 20 kV | [kV] | 42 / 5 min. | |
18 / 30 kV | [kV] | 63 / 5 min. | |
Temperature range | in motion | -20°C till +90°C | |
fixed | -20°C till +90°C | ||
Operating temperature | short circuit | °C | 250 |
Short circuit time | max. | [sec] | 5 |
Bending radius | min. | x diameter | 15 |
Flammability | standard | EN 50265-2-1 |
Nom. Cross-section of conductor | Strands No./Dia. Of Conductor | Insulation Thickness | Inner Sheath Thickness | Steel Tape Thickness | Sheath Thickness | Approx. O.D. | Approx. Weight | Max. D.C Resistance of Conductor (20 ℃) | Testing Voltage A.C | Current Rating | |
mm2 | pc/mm | mm | mm | mm | mm | (mm) | kg/km | Ω /km | kV/5min | In air (A) | In soil(A) |
3 × 35 | 7/2.52 | 5.5 | 1.8 | 2 × 0.5 | 2.9 | 58.0 | 4840 | 0.524 | 42 | 140 | 155 |
3 × 50 | 10/2.52 | 5.5 | 1.8 | 2 × 0.5 | 3.0 | 61.0 | 5463 | 0.387 | 42 | 165 | 180 |
3 × 70 | 14/2.52 | 5.5 | 2.0 | 2 × 0.5 | 3.1 | 65.0 | 6446 | 0.268 | 42 | 210 | 220 |
3 × 95 | 19/2.52 | 5.5 | 2.0 | 2 × 0.5 | 3.2 | 68.0 | 7457 | 0.193 | 42 | 255 | 265 |
3 × 120 | 24/2.52 | 5.5 | 2.0 | 2 × 0.5 | 3.3 | 71.0 | 8459 | 0.153 | 42 | 290 | 300 |
3 × 150 | 30/2.52 | 5.5 | 2.2 | 2 × 0.5 | 3.4 | 75.0 | 10555 | 0.124 | 42 | 330 | 340 |
3 × 185 | 37/2.52 | 5.5 | 2.2 | 2 × 0.5 | 3.5 | 78.0 | 11925 | 0.0991 | 42 | 375 | 380 |
3 × 240 | 48/2.52 | 5.5 | 2.2 | 2 × 0.8 | 3.7 | 83.0 | 13959 | 0.0754 | 42 | 435 | 435 |
3 × 300 | 61/2.52 | 5.5 | 2.2 | 2 × 0.8 | 3.9 | 88.0 | 16314 | 0.0601 | 42 | 495 | 485 |
3 × 400 | 61/2.97 | 5.5 | 2.3 | 2 × 0.8 | 4.1 | 95.0 | 19032 | 0.047 | 42 | 565 | 520 |
Certificates
ISO,CE, KEMA ,IEC, RoHS, CCC, P3C and more others at request
Ordering Advice
Rated Voltage
Application Standard:IEC/BS/UL/GB
Number of Cores
Conductor Size $ Construction
Type of Insulation
Armored or unarmored. If armour, the armour type & material
The Requirement of Sheath
Length of Cable & Packing Requirement
Other Requirement