Send Message
Qingdao Yilan Cable Co., Ltd. 86-- 18724796885 atwood.lee@hold-one.com
3x95SQ MM 25mm 3 Core Electrical Cable , Armored Cable Wiring URD 6.35/11KV

3x95SQ MM 25mm 3 Core Electrical Cable , Armored Cable Wiring URD 6.35/11KV

  • High Light

    armored cable wiring

    ,

    armoured power cable

  • Screen
    Copper Wire
  • Standard
    AS/NZS 1429
  • Insulation Thickness
    3.4mm
  • Operating Temp
    90 Degree
  • Conductor
    Stranded Copper
  • Sample
    Free
  • Place of Origin
    China
  • Brand Name
    HOLD-ONE
  • Certification
    KEMA/CE/ISO/TUV
  • Minimum Order Quantity
    500M
  • Price
    USD 6.89-105.8/M
  • Packaging Details
    Wooden Drum
  • Delivery Time
    7 Days
  • Payment Terms
    L/C, T/T
  • Supply Ability
    58726KM/Week

3x95SQ MM 25mm 3 Core Electrical Cable , Armored Cable Wiring URD 6.35/11KV

Three Core URD 6.35/11KV SWA Armoured Electrical Cable XLPE 3x95SQMM By AS Standard

 

 

Construction

 

Conductor Compact Stranded Copper Conductor, Class 2 as per IEC 60228
Circular solid Copper Conductor, Class 1 as per IEC 60228
Flexible Stranded Copper Conductor, Class 5 as per IEC 60228
Conductor Screen Semi-conductor
Insulation XLPE(Cross-linked polyethylene)
Insulation Screen Semi-conductor
Metalic Shield Copper Tape Screen or Copper wire & copper tape Shield
Filler Fillers strip
Wrapping Tape Non woven wrapping tape or lsoh wrapping tape
Inner Covering Extruded PVC, or LSOH
Armour Steel Tape Armour
Overall Sheath PVC, FR-PVC, PE or LSOH
 

 

 

This product is applicable to the power transmission and distribution line with AC rated voltage(U0/U) of 3.6/6kV-26/36kV system.It is routed in air (cable bridge frame,indoor wall support,and tray) and soil(direct buried, cable trench,pipe ect.) respectively according to difference of the protection layer structure.
 

Standards

 

International: IEC 60502-2, IEC 60228

China: GB/T 12706.2-2008

Other standards such as BS,DIN and ICEA upon request

 

Applications

 

Used for power transmission and distribution line with voltage rated at 35kV and below.

Compared with PVC Insulated Power Cable, xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working.

 

Specifications

 

MV(6 to 35kv) Power Cable
Model and Description Uo/U(Um)=3.6/6(7.2), 6/6(7.2), 6/10(12), 8.7/10(12), 8.7/15(17.5), 12/20(24), 18/30(36), 21/35(40.5), 26/35(40.5)kV No.of Core Conductor cross-section area(mm2)
xlpe insulation 1 core 3 core 10 16 25 35 70 95 120 150 185 240 300 400 500 630 sq mm
Cu core Al Core
YJV, N2XSY;PVC sheathed power cable YJLV, NA2XSY; PVC sheathed power cable
YJV22;steel tape armoured,PVC sheathed power cable YJLV22;steel tape armoured,PVC sheathed power cable
YJV32,YJV42;steel wire armoured ,PVC sheathed power cable YJLV32,YJLV42;steel wire armoured ,PVC sheathed power cable
pvc insulation
Cu Core Al Core
VV(VY);PVC(PE)sheathed power cable VLV(VLY);PVC(PE)sheathed power cable
VV22(VV23);steel tape armoured,PVC(PE)sheathed power cable VLV22(VLV23);steel tape armoured,PVC(PE)sheathed power cable
VV32(VV33),VV42(VV43);steel wire armoured ,PVC(PE)sheathed power cable VLV32(VLV33),VLV42(VLV43);steel wire armoured ,PVC(PE)sheathed power cable

 


Technical data

 

Test voltage 6 / 10 kV [kV] 21 / 5 min.
  12 / 20 kV [kV] 42 / 5 min.
  18 / 30 kV [kV] 63 / 5 min.
Temperature range in motion   -20°C till +90°C
  fixed   -20°C till +90°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard   EN 50265-2-1

 

Nom. Cross-section of conductor Strands No./Dia. Of Conductor Insulation Thickness Inner Sheath Thickness Steel Tape Thickness Sheath Thickness Approx. O.D. Approx. Weight Max. D.C Resistance of Conductor (20 ℃) Testing Voltage A.C Current Rating
mm2 pc/mm mm mm mm mm (mm) kg/km Ω /km kV/5min In air (A) In soil(A)
3 × 35 7/2.52 5.5 1.8 2 × 0.5 2.9 58.0 4840 0.524 42 140 155
3 × 50 10/2.52 5.5 1.8 2 × 0.5 3.0 61.0 5463 0.387 42 165 180
3 × 70 14/2.52 5.5 2.0 2 × 0.5 3.1 65.0 6446 0.268 42 210 220
3 × 95 19/2.52 5.5 2.0 2 × 0.5 3.2 68.0 7457 0.193 42 255 265
3 × 120 24/2.52 5.5 2.0 2 × 0.5 3.3 71.0 8459 0.153 42 290 300
3 × 150 30/2.52 5.5 2.2 2 × 0.5 3.4 75.0 10555 0.124 42 330 340
3 × 185 37/2.52 5.5 2.2 2 × 0.5 3.5 78.0 11925 0.0991 42 375 380
3 × 240 48/2.52 5.5 2.2 2 × 0.8 3.7 83.0 13959 0.0754 42 435 435
3 × 300 61/2.52 5.5 2.2 2 × 0.8 3.9 88.0 16314 0.0601 42 495 485
3 × 400 61/2.97 5.5 2.3 2 × 0.8 4.1 95.0 19032 0.047 42 565 520

 

Certificates

 

ISO,CE, KEMA ,IEC, RoHS, CCC, P3C and more others at request

 

 

Ordering Advice

 

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement