logo
products
PRODUCTS DETAILS
Home > Products >
High Voltage Armoured Electrical Cable Three-Core XLPE Insulation Copper Wire Shield STA Underground Al Cable

High Voltage Armoured Electrical Cable Three-Core XLPE Insulation Copper Wire Shield STA Underground Al Cable

MOQ: 500 Meters
Price: US$0.5~120 per Meter
Standard Packaging: Wooden Drum or Steel
Delivery Period: 10-15 days
Payment Method: T/T, L/C
Supply Capacity: 10,000 KM / Month
Detail Information
Place of Origin
China
Brand Name
QINGDAO YICABLE CABLE
Certification
ISO,CE,IEC,TUV,KEMA
Product Type:
Underground Al Cable
Voltage:
High Voltage
Conductor:
Al / Aluminum
Insulation:
XLPE
Armor:
Steel Tape Armoring
Sreen:
Copper Wires
Cores:
Three-Core
Sheath Material:
PVC / PE / LSOH
Standards:
IEC / BS / IS / VDE
Warranty:
2 Years
Highlight:

armored electrical wire

,

armored cable wiring

Product Description

High Voltage Armoured Electrical Cable Three-Core XLPE Insulation Copper Wire Shield STA Underground Al Cable

 

 

Cable structure


- Round bare aluminum core stranded according to IEC 60228
- Inner semi-conductive layer
- Core insulation XLPE
- Color code according to HD 308 S2
- Outer semi-conductive layer
- Semi-conductive tape
- Copper wire & tape screen
- Filler
- PVC inner sheath
- Galvanized steel tape armour (STA)
- PVC outer sheath (red or black)

 

 

Application

 

These power armoured cables are designed for open air installation, for direct burrial underground, in water, in cable ducts, power stations, where mechanical damages to the cable may occur.

 

 


Technical data

 

- Power cable according to DIN VDE 0276 part 603, HD 620, IEC 60502, BS 6622
- Temperature range max. to +90 °C
- Temperature during installation from 0 °C to +70 °C
- Short circuit temperature +250 °C (up to 5 seconds)
- Nominal voltage Uo/U 3,6/6 kV, 6/10 kV, 6,35/11 kV (dle BS), 18/30 kV, 19/33 kV (dle BS)
- Operating voltages 3,6/6 kV = max. 7,2 kV  6/10 kV = max. 12 kV  18/30 kV = max. 36 kV
- Test voltage a.c. 3,6/6 kV = 11 kV up to 5 min.  6/10 kV = 21 kV up to 5 min. 18/30 kV = 63 kV up to 5 min.
- Minimum bending radius approx. 15 cable diameter

 

Test voltage 6 / 10 kV [kV] 21 / 5 min.
  12 / 20 kV [kV] 42 / 5 min.
  18 / 30 kV [kV] 63 / 5 min.
Temperature range in motion   -5°C till +70°C
  fixed   -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard   EN 60332-1-2

 

 

Table of the voltage, cores and cross-section

 

Item Category A ,B 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV 21/35kV
Category A ,B 6/6kV 8.7/10kV 12/15kV 18/20kV - 26/35kV
Single core mm2 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
Three core mm2 25-400 25-400 35-400 50-400 50-400 50-400

 

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.

 

 

Ordering Advice

 

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

 

High Voltage Armoured Electrical Cable Three-Core XLPE Insulation Copper Wire Shield STA Underground Al Cable 0

 

PACKING AND SHIPPING:
 
 

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

 

 

FAQ

 

1. Shipping: By sea or air due to heavy weight. Samples will be send by DHL, Fedex. etc

2. Payment: We accept T/T, L/C , just choose what you like

3. Delivery time: Generally 7~10 working days upon receipt deposit. According to the quantity.

4. MOQ: Generally our MOQ is 1000meters. samples below 20 centimeter can be provided freely.

 

 

Our Services

 

♦ We are the one of biggest manufacture of electric wire and power cable in China and has more than 20 years producing and marketing experience.

♦ We accept OEM. The cable size and material are customized.Ur own logo and own design are welcome. We will produce according to your requirement and description;

♦ Please send us inquiry for more products info and we will give you feedback in 12 hours.

 
products
PRODUCTS DETAILS
High Voltage Armoured Electrical Cable Three-Core XLPE Insulation Copper Wire Shield STA Underground Al Cable
MOQ: 500 Meters
Price: US$0.5~120 per Meter
Standard Packaging: Wooden Drum or Steel
Delivery Period: 10-15 days
Payment Method: T/T, L/C
Supply Capacity: 10,000 KM / Month
Detail Information
Place of Origin
China
Brand Name
QINGDAO YICABLE CABLE
Certification
ISO,CE,IEC,TUV,KEMA
Product Type:
Underground Al Cable
Voltage:
High Voltage
Conductor:
Al / Aluminum
Insulation:
XLPE
Armor:
Steel Tape Armoring
Sreen:
Copper Wires
Cores:
Three-Core
Sheath Material:
PVC / PE / LSOH
Standards:
IEC / BS / IS / VDE
Warranty:
2 Years
Minimum Order Quantity:
500 Meters
Price:
US$0.5~120 per Meter
Packaging Details:
Wooden Drum or Steel
Delivery Time:
10-15 days
Payment Terms:
T/T, L/C
Supply Ability:
10,000 KM / Month
Highlight

armored electrical wire

,

armored cable wiring

Product Description

High Voltage Armoured Electrical Cable Three-Core XLPE Insulation Copper Wire Shield STA Underground Al Cable

 

 

Cable structure


- Round bare aluminum core stranded according to IEC 60228
- Inner semi-conductive layer
- Core insulation XLPE
- Color code according to HD 308 S2
- Outer semi-conductive layer
- Semi-conductive tape
- Copper wire & tape screen
- Filler
- PVC inner sheath
- Galvanized steel tape armour (STA)
- PVC outer sheath (red or black)

 

 

Application

 

These power armoured cables are designed for open air installation, for direct burrial underground, in water, in cable ducts, power stations, where mechanical damages to the cable may occur.

 

 


Technical data

 

- Power cable according to DIN VDE 0276 part 603, HD 620, IEC 60502, BS 6622
- Temperature range max. to +90 °C
- Temperature during installation from 0 °C to +70 °C
- Short circuit temperature +250 °C (up to 5 seconds)
- Nominal voltage Uo/U 3,6/6 kV, 6/10 kV, 6,35/11 kV (dle BS), 18/30 kV, 19/33 kV (dle BS)
- Operating voltages 3,6/6 kV = max. 7,2 kV  6/10 kV = max. 12 kV  18/30 kV = max. 36 kV
- Test voltage a.c. 3,6/6 kV = 11 kV up to 5 min.  6/10 kV = 21 kV up to 5 min. 18/30 kV = 63 kV up to 5 min.
- Minimum bending radius approx. 15 cable diameter

 

Test voltage 6 / 10 kV [kV] 21 / 5 min.
  12 / 20 kV [kV] 42 / 5 min.
  18 / 30 kV [kV] 63 / 5 min.
Temperature range in motion   -5°C till +70°C
  fixed   -20°C till +70°C
Operating temperature short circuit °C 250
Short circuit time max. [sec] 5
Bending radius min. x diameter 15
Flammability standard   EN 60332-1-2

 

 

Table of the voltage, cores and cross-section

 

Item Category A ,B 3.6/6kV 6/10kV 8.7/15kV 12/20kV 18/30kV 21/35kV
Category A ,B 6/6kV 8.7/10kV 12/15kV 18/20kV - 26/35kV
Single core mm2 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
Three core mm2 25-400 25-400 35-400 50-400 50-400 50-400

 

The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.

 

 

Ordering Advice

 

Rated Voltage

Application Standard:IEC/BS/UL/GB

Number of Cores

Conductor Size $ Construction

Type of Insulation

Armored or unarmored. If armour, the armour type & material

The Requirement of Sheath

Length of Cable & Packing Requirement

Other Requirement

 

 

High Voltage Armoured Electrical Cable Three-Core XLPE Insulation Copper Wire Shield STA Underground Al Cable 0

 

PACKING AND SHIPPING:
 
 

We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.

Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

 

 

FAQ

 

1. Shipping: By sea or air due to heavy weight. Samples will be send by DHL, Fedex. etc

2. Payment: We accept T/T, L/C , just choose what you like

3. Delivery time: Generally 7~10 working days upon receipt deposit. According to the quantity.

4. MOQ: Generally our MOQ is 1000meters. samples below 20 centimeter can be provided freely.

 

 

Our Services

 

♦ We are the one of biggest manufacture of electric wire and power cable in China and has more than 20 years producing and marketing experience.

♦ We accept OEM. The cable size and material are customized.Ur own logo and own design are welcome. We will produce according to your requirement and description;

♦ Please send us inquiry for more products info and we will give you feedback in 12 hours.

 
Sitemap |  Privacy Policy | China Good Quality XLPE Insulated Cable Supplier. Copyright © 2020-2025 Qingdao Yilan Cable Co., Ltd. . All Rights Reserved.