Send Message
Qingdao Yilan Cable Co., Ltd. 86-- 18724796885 atwood.lee@hold-one.com
Fireproof Single Core XLPE Insulated Cable For Industrial IEC 60502-1 Standard

Fireproof Single Core XLPE Insulated Cable For Industrial IEC 60502-1 Standard

  • High Light

    xlpe power cable

    ,

    cross linked polyethylene cable

  • Name
    Cross Linked Polyethylene Wire
  • Conductor Material
    Copper
  • Standard
    IEC 60502-1 Standard
  • Outer Sheath
    PVC
  • Color
    Customized
  • Type
    Fireproof
  • Place of Origin
    China
  • Brand Name
    HOLD-ONE
  • Certification
    CE/IEC/KEMA/VDE
  • Minimum Order Quantity
    Negotiable
  • Price
    Negotiable
  • Packaging Details
    Iron-wooden Drum or Whole Wooden Drum
  • Delivery Time
    8-15 days
  • Payment Terms
    L/C, T/T
  • Supply Ability
    100km per Month

Fireproof Single Core XLPE Insulated Cable For Industrial IEC 60502-1 Standard

Fireproof Single Core XLPE Insulated Cable For Industrial IEC 60502-1 Standard

 

Applications

 

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

Details

 

1. Conductors

------------------------------------------------------------------------------------------------------

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

------------------------------------------------------------------------------------------------------

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

------------------------------------------------------------------------------------------------------

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

------------------------------------------------------------------------------------------------------

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

------------------------------------------------------------------------------------------------------

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

 

Physical and Electrical Characteristics:

 

 

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
1×1.5 0.7 1.4 5.8 45 32 43 12.1
1×2.5 0.7 1.4 6.2 57 42 57 7.41
1×4.0 0.7 1.4 6.7 75 56 74 4.61
1×6.0 0.7 1.4 7.2 97 70 93 3.08
1×10 0.7 1.4 8.2 142 97 127 1.83
1×16 0.7 1.4 9.2 205 125 167 1.15
1×25 0.9 1.4 10.8 304 165 216 0.73
1×35 0.9 1.4 11.8 403 200 261 0.52
1×50 1.0 1.4 13.3 555 245 311 0.39
1×70 1.1 1.4 15.3 756 305 388 0.27
1×95 1.1 1.5 17.1 1005 375 461 0.19
1×120 1.2 1.5 18.7 1250 435 527 0.15
1×150 1.4 1.6 20.9 1561 500 592 0.12