Send Message
Qingdao Yilan Cable Co., Ltd. 86-- 18724796885 atwood.lee@hold-one.com
YJV Type Cross Linked Polyethylene Wire / Earth Core XLPE Power Cable

YJV Type Cross Linked Polyethylene Wire / Earth Core XLPE Power Cable

  • High Light

    xlpe power cable

    ,

    cross linked polyethylene cable

  • Name
    Cross Linked Polyethylene Wire
  • Conductor Material
    Copper
  • Standard
    IEC 60502-1
  • Outer Sheath
    PVC
  • Color
    Customized
  • Type
    YJV Type
  • Place of Origin
    China
  • Brand Name
    HOLD-ONE
  • Certification
    CE/IEC/KEMA/VDE
  • Minimum Order Quantity
    Negotiable
  • Price
    Negotiable
  • Packaging Details
    Iron-wooden Drum or Whole Wooden Drum
  • Delivery Time
    8-15 days
  • Payment Terms
    L/C, T/T
  • Supply Ability
    100km per Month

YJV Type Cross Linked Polyethylene Wire / Earth Core XLPE Power Cable

IEC 60502-1 Unarmoured XLPE Insulated Cable With Cu - Conductor Durable

 

Details

 

1. Conductors

------------------------------------------------------------------------------------------------------

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
2. Insulation

------------------------------------------------------------------------------------------------------

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
3. Assembly / Inner Covering

------------------------------------------------------------------------------------------------------

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
4. Armour

------------------------------------------------------------------------------------------------------

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
5. Outer Sheath

------------------------------------------------------------------------------------------------------

Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

 

Applications

 

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

 

Parameter

 

No.cores x

cross-sec.

Insulation

thickness

Nominal

Sheath

thickness

Outer Ø

approx.

weight

approx.

Current ratings in air 30℃ Current ratings buried 20℃
Phase Neutral
mm² mm mm mm mm kg / km A A
4×4+1×2.5 0.7 0.7 1.8 14.2 320 38 48
4×6+1×4.0 0.7 0.7 1.8 15.6 427 48 60
4×10+1×6.0 0.7 0.7 1.8 18.1 636 66 81
4×16+1×10 0.7 0.7 1.8 20.8 941 88 107
4×25+1×16 0.9 0.7 1.8 24.9 1441 118 137
4×35+1×16 0.9 0.7 1.8 27.1 1853 144 165
4×50+1×25 1.0 0.9 1.9 31.6 2616 177 196
4×70+1×35 1.1 0.9 2.1 36.5 3578 227 244
4×95+1×50 1.1 1.0 2.2 41.6 4843 277 288
4×120+1×70 1.2 1.1 2.4 46.3 6110 325 329
4×150+1×70 1.4 1.1 2.5 51.2 7421 375 369
4×185+1×95 1.6 1.1 2.7 56.8 9191 433 418
4×240+1×120 1.7 1.2 2.9 63.2 11763 518 488