Electrical ABC Aerial Bundled Cables Three Core For Under Ground / Villages Electrification
Product name Aerial Bundled Cable Overhead cable with Aluminum conductor
NFA2X NFC33-209, TS HD 604 S1
NFC33-209, TS HD 604 S1, GB/T 12706.1-2008.
CE, CCC, KEMA /
0.6/1kV, suitable for underground burying
Constructions
Conductor: Plain circular stranded aluminum conductor, conforms to IEC 60228 class 2
Insulation: PVC
Note: Insulation color as per standards or at request
Applications
ABC cable especially used at areas where the cost of under ground networks is expensive and also for electrification of rural areas like villages .
Standards
International: NFC33-209, TS HD 604 S1
China: GB/T 12706.1-2008
Other standards such as BS,DIN and ICEA upon request
Technical data
Rated voltage: 0.6/1kV
Max. Conductor Temp.: normal (90℃), short circuit no more than 5 s (250℃ when section-area below 300mm2,)
Certificates
CE, RoHS, CCC, KEMA and more others at request
Schedule of technical particulars
Phase conductor | |||||||||||
Nominal cross-sectional area | mm² | 16 | 16 | 25 | 35 | 50 | 70 | 95 | 120 | 150 | 185 |
Number of cores | 1 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |
Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 12 | 15 | 15 | 30 | 30 | |
Nominal insulation thickness | mm | 1 | 1 | 1.2 | 1.2 | 1.4 | 1.4 | 1.6 | 1.6 | 1.8 | 2.0 |
Diameter of insulated core | mm | 6.8 | 6.8 | 8.5 | 9.5 | 11.2 | 13.0 | 15.1 | 16.6 | 18.4 | 20.6 |
Max. DC resistance at 20℃ | ohm/km | 1.91 | 1.91 | 1.20 | 0.868 | 0.641 | 0.443 | 0.320 | 0.253 | 0.206 | 0.164 |
Current rating at still wind, ambient | A | 61 | 61 | 84 | 104 | 129 | 167 | 209 | 246 | 283 | 332 |
temperature=30℃ | |||||||||||
Conductor temperature=75℃ | |||||||||||
Messenger conductor | |||||||||||
Nominal cross-sectional area | mm² | 25 | 25 | 25 | 25 | 35 | 50 | 70 | 70 | 95 | 120 |
Minimum number of wires | 6 | 6 | 6 | 6 | 6 | 6 | 12 | 12 | 15 | 15 | |
Nominal insulation thickness | mm | 1.2 | 1.2 | 1.2 | 1.2 | 1.2 | 1.4 | 1.4 | 1.4 | 1.6 | 1.6 |
Diameter of insulated core | mm | 8.5 | 8.5 | 8.5 | 8.5 | 9.5 | 11.2 | 13.1 | 13.1 | 15.1 | 16.6 |
Max. DC resistance at 20℃ | ohm/km | 1.312 | 1.312 | 1.312 | 1.312 | 0.943 | 0.693 | 0.469 | 0.469 | 0.349 | 0.273 |
Calculated breaking load | kN | 6.4 | 6.4 | 6.4 | 6.4 | 8.9 | 12.1 | 18.0 | 18.0 | 24.2 | 30.8 |
Completed cable | |||||||||||
Approx. overall diameter | mm | 15.3 | 19.0 | 23.2 | 25.6 | 30.0 | 34.9 | 40.6 | 44.1 | 49.2 | 54.9 |
Approx. weight of cable | kg/km | 160 | 290 | 400 | 500 | 680 | 920 | 1270 | 1510 | 1870 | 2340 |
Packing length | m/drum | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 500 | 500 | 500 | 500 |